600 × 600 stepped-edge panels with square-groove grid
Reading the Drawing
Panels rest inside the visible grid formed by main and cross members. The section and profile views show how the stepped panel edge sits in the grid.
Numbered Component Key
Match each number to the label below. Dimensions shown on the drawing are in millimeters unless noted.
- 600 module stepped-edge grid
- Main grid member
- Cross grid member
- 600 × 600 stepped-edge panel
- 8 mm edge return
- M8 expansion anchor
- M8 galvanized hanger rod
- 38/50 main-carrier hanger
- Stepped-grid hanger
- 38/50 main carrier
- Stepped-edge grid
- Edge return height
Installation Steps
- Measure the finished ceiling elevation from the design drawings. Mark the level line and fix the perimeter angle along the walls.
- Drill the suspension points and fix the hanger rods with expansion anchors.
- Fit the main-carrier hangers and light-steel main carriers. Adjust their height and level, keeping the carriers parallel.
- Use the stepped-grid hangers to connect the main grid members to the light-steel carriers. Join the main grid members and insert the cross members into them.
- Gently place the panels into the squares formed by the main and cross grid members, then align them.
- Measure perimeter panels on site, cut them to fit and support their edges on the perimeter angle.