A perforated aluminum panel is specified in two parts: the hole geometry and, where sound absorption matters, the acoustic build-up behind it. This guide calculates square and staggered open area, deducts solid borders, and shows what to check in an acoustic report. Open area tells you how much of the face is holes; the acoustic rating (NRC) comes from the panel plus its backing.
Which perforation and backing options does Lianhui offer?
Lianhui perforates panels by CNC and turret punching with Ø3–25 mm holes and a 10–45% perforated-field open area. Solid fixing borders are at least 20 mm wide; the fabrication drawing fixes hole pitch, sheet thickness, returns and any wider margins.
Factory-bonded acoustic non-woven fleece is available as an option. Specify the hole pattern and backing together, because acoustic performance belongs to the complete installed assembly.
Perforation open-area calculator
Round holes only. Pitch is the distance from one hole centre to the next, not the clear gap between holes.
For d = 3 mm and p = 6 mm, open area is 19.63% on a square grid or 22.67% on a 60° staggered grid.
Geometric result for the perforated field only. Solid borders, folds and unperforated zones reduce the open area of the whole panel. This is not an acoustic, airflow, fire or structural performance rating.
How do you calculate open area from diameter and pitch?
For round holes on a square grid, field open area = π × d² ÷ (4 × p²) × 100%, where d is the hole diameter and p the centre-to-centre pitch. This gives the repeating pattern before borders and service openings.
| Hole diameter d | Pitch p | Metal between holes p − d | Nominal field open area |
|---|---|---|---|
| 4 mm | 10 mm | 6 mm | 12.6% |
| 3 mm | 6 mm | 3 mm | 19.6% |
| 3 mm | 5 mm | 2 mm | 28.3% |
The last two rows use the same hole: the tighter pitch adds open area and narrows the metal between holes, which changes both the look and how the sheet behaves in forming.
For a regular 60° staggered layout, open area = π × d² ÷ (2 × √3 × p²) × 100%, with p between nearest centres. Ø3 mm at 6 mm staggered gives about 22.7%, against 19.6% on a square grid, so always state the layout along with “3 mm holes at 6 mm centres”.
Why include solid borders in the panel-level calculation?
Calculation: a 600 × 600 mm face with a 20 mm solid border on all sides has a 560 × 560 mm perforated field, 87.1% of the face. With the 3 mm / 6 mm square pattern, whole-face open area is 19.6% × 87.1% = 17.1%.
This estimate ignores partial rows at the pattern edge; the production hole map gives the exact count. When a specification says “20% open area”, confirm whether it means the perforated field or the whole face so that all quotations price the same panel.

What does the acoustic backing do?
Holes let sound reach the material and cavity behind the face. Acoustic fleece and a separate absorbent infill are different components, so specify the backing product, its position and any infill separately.
When comparing acoustic reports, match the tested hole pattern, backing, infill and mounting to your ceiling. A report describes the tested assembly; it does not transfer to every panel with the same hole size.
Absorption within a room and transmission between rooms are different questions. NRC rates absorption; CAC rates attenuation between rooms through a shared ceiling void. Meeting-room privacy needs a CAC figure, not an NRC.
How do you specify a pattern the factory can reproduce?
- Panel face dimensions and aluminum thickness.
- Hole shape, diameter and spacing in both directions.
- Square, staggered or other layout, with an orientation arrow where needed.
- Solid borders at edges, bends and service cut-outs.
- Finish, backing type and any infill or cavity requirement.
- Whether the open-area target applies to the field or the whole face.
For image perforation, send the approved artwork; it stays linked to the panel divisions and hole map, and each panel carries a sequence number so the image assembles in the right order.
What does “20% perforation” need to say in an enquiry?
Ambiguous: “600 mm acoustic panel, 3 mm holes, approximately 20% open.”
Defined geometry: “600 × 600 mm finished face; Ø3 mm round holes on a 6 × 6 mm square grid; 20 mm solid border on each edge; nominal field open area 19.6%; approximate whole-face open area 17.1% before additional openings.”
Add aluminum thickness, finish, backing product and the acoustic requirement to complete the line item.
On the same square grid, the metal between holes is 6 − 3 = 3 mm. A 5 mm pitch leaves 2 mm and raises field open area to 28.3%. Check a changed pattern against sheet thickness, bends and borders before adopting it to reach a target percentage.
Draw a solid margin around light openings and access cuts. For the final whole-face percentage, take the open-hole area from the production hole map and divide by the defined face area.
Why approve a backed sample, not just a bare sheet?
Review the pattern from the real viewing distance with the chosen backing color: black fleece makes holes read darker than an unbacked sample against a white wall. Check borders across two adjacent panels and include one typical light or grille cut-out. Sample production takes 3–5 working days, excluding shipping.
Measure hole size, pitch and borders on the sample, and check acoustic performance against the test report for the same backing, infill and mounting.
How do you read an acoustic report beyond its single-number rating?
Check the test method and specimen first. ASTM C423 measures absorption in a reverberation room; it is not a room-to-room isolation test. Read the frequency data as well as the single number when the room has a specific acoustic problem.
Match the tested perforation, backing, infill, cavity depth and mounting to your design. If the proposal drops the infill or changes the cavity, ask whether the report still covers it.
Is panel performance the same as room coverage?
Room acoustics depend on how much treatment there is and where, plus walls, glazing, floor finishes and room volume. Record the treated area after deducting lights, solid service zones and access pieces.
A 100 m² ceiling with 18 m² of solid service panels leaves 82 m² of perforated assembly. Give the acoustician this zone plan and the full assembly details for the room assessment.
How do you check the first production panel against the hole map?
- Measure hole size and pitch in both directions, including staggered orientation.
- Check the first and last rows against each border and service opening.
- Inspect burrs and coated hole edges; very small holes need attention to coating coverage and bridging.
- Check that the backing is continuous and well attached and does not block service access.
- Compare neighbouring panels so pattern and margins line up.
What should an acoustic ceiling panel enquiry include?
For perforated aluminum panels, send the layout, pattern drawing, face size, finish and backing, and say whether the goal is reverberation control, room-to-room privacy or decoration. For image-perforated panels, add the artwork and viewing direction. Lianhui quotes perforated ceilings from an MOQ of 150–200 m² per product category.
Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →