High-edge panels with V-type concealed carriers
Reading the Drawing
The raised panel edges engage with the concealed carriers. The lower drawings identify the carrier, connector and hanger.
Numbered Component Key
Match each number to the label below. Dimensions shown on the drawing are in millimeters unless noted.
- High-edge carrier
- M8 galvanized hanger rod
- No. 50 main carrier
- High-edge carrier hanger
- High-edge ceiling panel
- Carrier connector
Installation Steps
Components: M8 galvanized rods; light-steel main carriers; concealed-carrier hangers, carriers and connectors; high-edge panels.
- Measure the finished ceiling elevation from the design drawings. Mark the level line and fix the perimeter angle along the walls.
- Establish the installation direction. Drill suspension points in the structural ceiling at no more than 1,200 mm spacing and secure the galvanized hanger rods with expansion anchors.
- Fit the main-carrier hangers and light-steel main carriers. Adjust their height and level, keeping the carriers parallel.
- Use V-carrier hangers to connect the V-type concealed carriers to the main carriers. Level the secondary carriers; keep them parallel to one another and perpendicular to the main carriers.
- Align the two clip edges of the panel with the carrier slots. Gently press the panel edges upward until the returned edges engage in the carriers.
- Measure perimeter panels on site, cut them to fit and support their edges on the perimeter angle.