+86 180 2450 8117 [email protected] Foshan, Guangdong, China

What Should You Measure Before Ordering Aluminum Column Covers?

How to measure columns before ordering custom aluminum column covers: structure vs finished diameter, survey heights, joint set-out, backing frame and closure.

Curved aluminum surfaces divided by vertical and horizontal joints
Curved surfaces are divided into separate modules. The survey must locate the finished surface and each joint, rather than specify a diameter alone.
The Short Answer

Measure the existing column at several heights against the building grid, define the finished cladding diameter (structure + 2 × build-up), and set out joints and the backing frame from common datums. Lianhui makes round, rectangular and custom column covers in panels up to 4,000 mm long, fabricated from your survey and approved drawings.

A nominal column diameter is not enough to make an aluminum cover. We also need the finished surface position, how the enclosure is divided and what sits behind it.

Lianhui’s aluminum column cladding covers round, rectangular and custom outlines, in panels up to 4,000 mm long; radius and module height come from your site dimensions and the shop drawings. Survey the enclosure first, then detail the panels.

Why separate the structural column from the finished surface?

Draw the structural outline and the finished cladding outline as two separate lines. The space between them holds the frame, brackets, connections and construction allowance.

For a circular column with uniform build-up, Dfinished = Dstructure + 2s. A 600 mm column with a 50 mm radial build-up gives a 700 mm finished diameter. Offset or irregular structures need coordinates or sections.

Why measure shape and position at more than one height?

A tape gives circumference; dividing by π gives the diameter of an ideal circle, not the real shape or whether the centre drifts up the height.

Record two perpendicular diameters or a surveyed outline at base, mid-levels and top, each located on the project grid, with protrusions, section changes, nearby walls, floor edges and ceiling soffit. Match survey accuracy to the drawing tolerances.

Survey item Record on the drawing Why it changes fabrication
Existing outline Section dimensions and grid position at identified elevations Detects taper, ovality or an offset centre
Finished envelope Visible-face radius or outline, with its reference surface Defines the formed geometry
Vertical extent Finished floor, ceiling junction and intermediate breaks Locates panel ends and horizontal joints
Obstructions Brackets, services and adjacent finishes with coordinates Checks room for fixings and assembly

Why set out the joints before dividing the circle?

Fix the first vertical joint on a named grid direction and number the other divisions clockwise in a stated viewing direction, so curved pieces are not numbered from opposite sides.

Arc length is Rθ (θ in radians): a half-circle at 350 mm radius is about 1,100 mm. Joint gaps, sheet thickness, returns and forming allowances change the flat blank, so send the finished outline and we develop the cutting size.

Carry horizontal joint levels across neighbouring columns where alignment matters, and check every floor and ceiling junction individually.

How should the backing frame and closure sequence be resolved?

Lianhui’s standard column assembly uses vertical and horizontal square-tube framing, angle connectors and panel brackets, with backer rod and sealant at expressed joints. Confirm the connection and joint for your project with the project engineer.

Show how the last segment goes in and how its fixings are reached. If a wall, floor trim or neighbouring segment blocks the tool, change the sequence before fabrication, and include any access panel in the numbered layout.

What should a coordinated survey package include?

Send surveyed sections, finished-face plan, elevations, joint widths, numbered panel schedule, frame details and finish reference (powder, PVDF or wood-grain) under one revision, with units and any open dimensions marked. The shop drawing checklist covers the rest.

Send the column survey for drawing review (2–4 working days). Approve one complete enclosure and its closure detail before repeating it across the project.

Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →

Common Questions

Can the fabricator work from an approximate column diameter?

An approximate diameter can support an initial discussion. Fabrication needs the confirmed finished outline, measured structure, panel divisions and support details in the approved drawings.

Should every column on a repeated floor plan use the same survey?

Identify the actual columns and check the relevant levels and interfaces. A repeated drawing does not establish that every built column has the same position or geometry.

← All Technical Articles

Technical Blog

Fabrication, Finishes & Ceiling Details

Machining sequences, coating methods, panel sections and dimension tables.

All Technical Articles →

Quotation checklist & spec sheet

Drawing checklist and fields for alloy, dimensions, finish, fixing details and inspection tolerances.

Download RFQ Checklist (PDF) English PDF · 2 pages

Privacy settings

Essential functionality is always available. Google Analytics is optional and starts only with your permission. We do not use advertising trackers or embedded social widgets. Fonts are served by this website.

Essential functionality
Navigation, enquiry security and your privacy preference.
Optional analytics
Page visits, confirmed enquiries, and clicks on contact or download links. We do not send form entries, drawings, email addresses or telephone numbers to Analytics.
External links
WhatsApp and other linked services open only when you choose their links. Their own privacy policies then apply.

Your choice is remembered on this browser for up to 6 months. Turn this off and save to withdraw consent. Rejecting analytics does not affect enquiries.

After a successful inquiry, a temporary confirmation cookie connects the submission to its thank-you page. It contains a random reference, not your contact details or drawings, and expires within 10 minutes or is cleared when used.

Read the Privacy Policy →