A nominal column diameter is not enough to make an aluminum cover. We also need the finished surface position, how the enclosure is divided and what sits behind it.
Lianhui’s aluminum column cladding covers round, rectangular and custom outlines, in panels up to 4,000 mm long; radius and module height come from your site dimensions and the shop drawings. Survey the enclosure first, then detail the panels.
Why separate the structural column from the finished surface?
Draw the structural outline and the finished cladding outline as two separate lines. The space between them holds the frame, brackets, connections and construction allowance.
For a circular column with uniform build-up, Dfinished = Dstructure + 2s. A 600 mm column with a 50 mm radial build-up gives a 700 mm finished diameter. Offset or irregular structures need coordinates or sections.
Why measure shape and position at more than one height?
A tape gives circumference; dividing by π gives the diameter of an ideal circle, not the real shape or whether the centre drifts up the height.
Record two perpendicular diameters or a surveyed outline at base, mid-levels and top, each located on the project grid, with protrusions, section changes, nearby walls, floor edges and ceiling soffit. Match survey accuracy to the drawing tolerances.
| Survey item | Record on the drawing | Why it changes fabrication |
|---|---|---|
| Existing outline | Section dimensions and grid position at identified elevations | Detects taper, ovality or an offset centre |
| Finished envelope | Visible-face radius or outline, with its reference surface | Defines the formed geometry |
| Vertical extent | Finished floor, ceiling junction and intermediate breaks | Locates panel ends and horizontal joints |
| Obstructions | Brackets, services and adjacent finishes with coordinates | Checks room for fixings and assembly |
Why set out the joints before dividing the circle?
Fix the first vertical joint on a named grid direction and number the other divisions clockwise in a stated viewing direction, so curved pieces are not numbered from opposite sides.
Arc length is Rθ (θ in radians): a half-circle at 350 mm radius is about 1,100 mm. Joint gaps, sheet thickness, returns and forming allowances change the flat blank, so send the finished outline and we develop the cutting size.
Carry horizontal joint levels across neighbouring columns where alignment matters, and check every floor and ceiling junction individually.
How should the backing frame and closure sequence be resolved?
Lianhui’s standard column assembly uses vertical and horizontal square-tube framing, angle connectors and panel brackets, with backer rod and sealant at expressed joints. Confirm the connection and joint for your project with the project engineer.
Show how the last segment goes in and how its fixings are reached. If a wall, floor trim or neighbouring segment blocks the tool, change the sequence before fabrication, and include any access panel in the numbered layout.
What should a coordinated survey package include?
Send surveyed sections, finished-face plan, elevations, joint widths, numbered panel schedule, frame details and finish reference (powder, PVDF or wood-grain) under one revision, with units and any open dimensions marked. The shop drawing checklist covers the rest.
Send the column survey for drawing review (2–4 working days). Approve one complete enclosure and its closure detail before repeating it across the project.
Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →