A shop drawing is the document we cut, bend and coat from. It must define the face, returns, openings, brackets, joints and revision of every panel. An elevation shows the design intent; the shop drawing turns it into parts. At Lianhui, our engineers review drawings for custom solid aluminum panels in 2–4 working days before quoting.
How do installed module, finished face and cutting blank differ?
Three dimensions describe one panel. The installed module is the repeating layout. The finished face is the visible panel between joints. The cutting blank adds the material that becomes the folded returns, plus bend allowances.
| Drawing dimension | Definition or typical value | What it controls |
|---|---|---|
| Repeating module | 1,200 mm, measured between corresponding points on adjacent panels | Elevation setting-out and support coordination |
| Finished face width | 1,190 mm when one 10 mm joint is allocated to each repeat | Visible panel width; perimeter conditions are checked separately |
| Return depth | Dimensioned independently on the section | Edge geometry and clearance behind the face |
| Flat blank width | Developed from the finished section | Cutting; not simply the face plus two nominal returns |
The 10 mm joint is a setting-out dimension. Bend radius, sheet thickness and forming method set the developed blank, so supply the finished geometry and agree who prepares the flat pattern. Two parties using different bend allowances will cut different blanks from the same section.
Why give every hole and bracket a reference edge?
Pick one datum, such as the lower-left corner of the finished face, and dimension every opening from it. State whether a dimension locates a hole centre, an opening edge or a slot centre, and show slot direction, length and width. Coordinates from a common datum are faster to inspect than a chain of dimensions, which hides accumulated error at the last fixing.
Include a face view, sections through the returns and a rear view of the fittings. Label left-hand and right-hand parts separately. For curved panels, state the radius reference (inside or outside surface) and give arc, chord and height as separate values. Where the radius changes along a facade, supply a panel-numbered model or one section per geometry.
How do you draw the connection and the clearance it needs?
Stiffeners, brackets and support rails do different jobs: the stiffener keeps the panel flat, the bracket connects it, and the rail belongs to the support frame. Show all three on the rear view so they can be checked against anchors, insulation and service openings.
At corners, draw both adjoining panels and the joint between them, including sealant or joint strips where specified and the installer’s access to each fixing. Resolve the installation sequence before manufacture if a fixing becomes unreachable once the next panel is in place.
For ceiling panels, mark the pieces that must stay removable and the equipment reached through them. Show how each light fitting is supported; a cut-out on the ceiling plan only tells us where to cut.
How should tolerances be used to protect fit?
List the dimensions that control fit: face size, squareness, return angle, hole position, curvature and bracket location, each with its limit and measurement reference. Lianhui’s standard limits for solid panels are ±0.5° on bending angles and ≤1.5 mm diagonal difference; state any project-specific limit on the drawing.
For adjacent shaped panels, a trial assembly finds mismatches that single-panel measurements miss. Include the mating parts, joint spacers and supports in the trial, and check bracket engagement and fixing access as well as the visible face.
How do four small errors stack up at one fixing?
Suppose a drawing locates four successive features at 250 ±1 mm from the previous feature. The nominal final position is 1,000 mm. At the worst-case limits, all four positive or negative errors can accumulate: 996–1,004 mm.
If the functional requirement is for the last hole centre to be 1,000 ±1 mm from datum A, dimension and inspect that coordinate directly. Do not infer it from four individually acceptable chain dimensions.
The ±1 mm values illustrate how tolerances add up. If a drawing carries both chain and overall dimensions, state which one governs acceptance.
Name the viewing direction on the rear view. A hole 80 mm from the left edge in front view sits on the opposite side when seen from behind. Marking the same datum edge in both views prevents mirror-image brackets on otherwise identical panels.
How do you link the drawing revision to the panel and its finish?
| Field | Entry or required information |
|---|---|
| Identification | Panel P-014, elevation E-02, drawing revision C, quantity 12 — identifier format |
| Material | Alloy, temper and nominal sheet thickness; do not enter overall folded depth as thickness |
| Geometry | Face, returns, corner treatment, openings, curvature and rear fittings |
| Finish | Process, retained sample code, gloss, grain arrow and exposed surfaces to coat |
| Inspection and packing | Critical dimensions, trial-assembly requirement, panel label and installation zone |
When a cut-out moves, revise the part drawing and the layout, then remove the superseded file from the production package. If only some panels change, list their panel numbers so we can tell a replacement drawing from an additional order.
Who is responsible at each interface?
Appearance approval, structural design and fabrication release belong to different people. The architect approves the joint pattern, the facade engineer checks supports and fixing loads, the fabricator develops the part geometry, and the site team confirms surveyed dimensions.
Record who owns the support-structure survey, anchor positions, bracket adjustment, movement allowance and final setting-out. Mark dimensions still awaiting survey as hold points and leave those pieces out of the release schedule until they are measured.
How do you track approved drawings by panel ID and revision?
Keep a revision register with the current drawing, affected panel IDs, quantity, finish and release status. Before a change is agreed, we check whether the affected pieces are uncut, formed, coated or packed.
The editable model and its PDF should carry the same revision. If they conflict, hold the affected panels until one geometry is confirmed, and incorporate closed comments into the issued drawing rather than leaving them in email.
What belongs on a short release checklist?
- Units, dimensions and front/rear viewing direction are explicit.
- Panel IDs and quantities match the elevation and schedule.
- Material, thickness, finish and grain direction are identified.
- Returns, openings, stiffeners and brackets can be made and installed without clashes.
- Fit-critical tolerances, survey hold points and trial assemblies are resolved.
- Current drawings replace superseded files for every affected piece.
For moving joints, add the installation temperature and the connection movement strategy. The thermal-movement guide shows how to size the joint.
What should you send for a fabrication quotation?
- A dimensioned PDF and the editable drawing or model.
- A panel schedule with quantities, installation zones and current revisions.
- The finished section, connection detail and any trial assembly required.
- The finish (powder, PVDF or wood-grain), color reference and grain direction.
- Inspection requirements, delivery sequence and spare panels listed separately.
For custom aluminum panels, send the most complex corner or curved piece together with the typical panel; those details drive machining time more than the total area. The fabrication process guide shows where each drawing input is checked in production.
Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →