Before a double-curved panel is priced, state which surface the model represents, its units and revision, and the dimensions that must survive export. A colored 3D view helps orientation; fabrication needs geometry.
Which surface must the fabricator reproduce?
The model may describe the visible face, the sheet mid-surface or a support surface behind it. Adding sheet thickness to the wrong one moves the finished face and changes its fit with neighbouring panels.
State the reference on the release drawing. For a visible-face model, mark the material side and show how sheet thickness and returns extend behind it, with sections through curved edges, corners and brackets. Offsets follow the local surface normal, not a single global axis.
Lianhui’s double-curved and twisted panels are formed aluminum sheet up to 4,000 mm long. Width, curvature and fixings for each panel are confirmed in drawing review against the 3D surface and panel layout.
Why check the exchanged file, not just the native model?
Export the agreed format and reopen it in the receiving software. Check units, origin, axis directions and panel IDs, then one known distance, three non-collinear points and the visible-face direction to catch scale, shift, rotation or mirroring errors.
A 1,200 mm reference edge should read 1,200 mm (or 1.2 m) in the received file, not 1.2 mm. Check a second dimension in another direction too.
Agree whether we need exact surfaces or solids; a display mesh only approximates the surface. Check that import keeps solids, surfaces and the coordinate system as intended.
How do sections check shape, joints and support?
Matching edges do not prove a matching surface. Pick inspection sections through the strongest curvature, a typical joint and each critical fixing, each located from the agreed datum so designer, factory and inspector compare the same geometry.
| Check | Compare against the released model | Why it matters |
|---|---|---|
| Panel boundary | Corners, trim lines and joint edges | Confirms the panel occupies its allocated position |
| Surface sections | Specified sections or agreed measurement points between edges | Checks the curved shape beyond its outline |
| Neighbouring panel | Joint width and face relationship along the shared boundary | Reveals local steps or a joint that varies unintentionally |
| Returns and brackets | Depth, orientation, hole locations and tool access | Checks the connection to the support and the installation sequence |
| Handed parts | Visible-face direction and marked installation position | Prevents a mirrored piece being treated as an identical repeat |
Where the surface should flow across a joint, check surface direction on both sides as well as the gap; where a crease is intended, record it.
Why agree first-piece inspection before series production?
Inspect a representative difficult panel, not the flattest one. Agree datum, support condition, method, locations and tolerances beforehand, because a panel measured unsupported can differ from the same panel in its frame.
For critical junctions, include the adjoining piece or a reference fixture, and record boundary, sections, joint and fixing fit separately from finish approval.
If a point is out of tolerance, trace whether the cause is the model, the file transfer, fabrication or support before changing production data, and keep the corrected first-piece record with the approved revision.
How do you compare the exported and received model?
Have the recipient check the imported file against a short control record: one overall dimension, one identifiable point and one asymmetric feature expose scale, origin and mirroring errors that a plausible screenshot hides.
| Control | Sender records | Receiver checks |
|---|---|---|
| File identity | Panel ID, revision, format, export date and units | Same file and revision opened |
| Scale | A known dimension, such as a 1,200 mm reference edge | Imported measurement equals the stated value |
| Position | Named datum point and axis orientation | Coordinates and axes agree |
| Handedness | A labelled asymmetric corner or fixing detail | Feature remains on the intended side |
| Geometry | Intended visible surface, edge boundaries and openings | No missing faces, reversed surface or unintended healing |
Attach annotated views of any mismatch to the same revision record and resolve it before release.
What should one coordinated fabrication package contain?
Send the model and units, datum, numbered panel layout, dimensioned sections, thickness and returns, fixing details, finish and inspection requirements, with repeated and mirrored pieces marked. Packing labels and installation drawings use the same panel IDs.
When a support or panel boundary changes, update the surface, brackets, neighbouring joints and inspection sections together and reissue the model with the drawing. Send the package through the curved-panel enquiry form; the shop drawing checklist covers the rest of the order.
Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →