Shaped baffles with matching shaped-baffle carriers
Reading the Drawing
Dedicated hangers connect the shaped-baffle carriers to the main framework. The lower views identify the baffle profile and its matching carrier fittings.
Component list
All dimensions in mm.
- M8 galvanized hanger rod
- 38/50 main-carrier hanger
- Shaped-baffle carrier
- 38/50 main carrier
- Shaped-baffle hanger
- Shaped baffle
- Galvanized hanger rod
Installation Steps
- Measure and mark the finished ceiling elevation.
- Establish the installation direction. Drill suspension points in the structural ceiling at no more than 1,200 mm spacing and secure the galvanized hanger rods with expansion anchors.
- Fit the main-carrier hangers and light-steel main carriers. Adjust their height and level, keeping the carriers parallel.
- Connect the shaped-baffle carriers to the main carriers using dedicated shaped-baffle hangers. Keep the secondary carriers parallel to one another, perpendicular to the main carriers and no more than 1,200 mm apart.
- Clip the shaped baffles into the shaped-baffle carriers and make the final alignment adjustments.
- Wear clean gloves when handling finished panels.