Open-cell grille assembly
Reading the Drawing
Main and cross strips interlock to form the open-cell module. Dedicated grille hangers connect the assembled modules to the suspended main carriers.
Numbered Component Key
Match each number to the label below. Dimensions shown on the drawing are in millimeters unless noted.
- Main grille strip
- Cross grille strip
- M8 galvanized hanger rod
- 38/50 main-carrier hanger
- 38/50 main carrier
- Grille hanger
Installation Steps
- Assemble the main strips below the cross strips. Insert the cross strips downward into the main strips, keeping each group parallel.
- Suspend and level the light-steel main carriers to the design elevation; keep them parallel.
- Assemble the grille on a workbench to the required lengths. The illustrated method uses typical 2,000 × 2,000 mm modules.
- Hang each module from the main carriers using the dedicated grille hangers. Connect neighboring modules by engaging the cross strips.
- Make small alignment adjustments after the modules are hung.
- Finish the perimeter with an edge angle.
- Keep hands clean during installation. Avoid sweat, oil and other contamination on the finished surface.