Deep square-edge S-shaped strips
Reading the Drawing
Use square-edge S strips with the corresponding deep square-edge carrier. The component profile and assembly section identify this connection.
Component list
All dimensions in mm.
- M8 galvanized hanger rod
- 38/50 main-carrier hanger
- Deep square-edge carrier
- Deep close-joint carrier
- Deep-profile carrier
- Strip-carrier hanger
- Deep square-edge S strip
- Widths: 150 / 200 / 300 mm
- Galvanized hanger rod
- 38/50 main carrier
- Width
Installation Steps
- Measure the finished ceiling elevation from the design drawings. Mark the level line and fix the perimeter angle along the walls.
- Establish the installation direction. Drill suspension points in the structural ceiling at no more than 1,200 mm spacing and secure the galvanized hanger rods with expansion anchors.
- Fit the main-carrier hangers and light-steel main carriers. Adjust their height and level, keeping the carriers parallel.
- Use strip hangers to connect the deep square-edge strip carriers to the main carriers. Level the secondary carriers; keep them parallel to one another and perpendicular to the main carriers.
- Fit the square-edge S-shaped strips into the matching secondary-carrier clips, working in one direction.
- Measure perimeter panels on site, cut them to fit and support their edges on the perimeter angle.
- Wear clean gloves when handling finished panels.