What changes when the joint becomes part of the design?
A joint is both a visible line and the edge between fabricated panels. On a large elevation, a small change in repeated joint width changes the rhythm of the whole surface. Close joints minimize the line; expressed joints make the module a deliberate part of the design.
In both cases each panel keeps its own edges and supports, so close-joint layouts need accurate setting-out: irregular supports show up as wandering lines or uneven faces.
How do Lianhui’s two systems compare?
| Selection point | Close-joint panels | Expressed-joint panels |
|---|---|---|
| Visual effect | Narrow joints and a continuous-looking finish | A visible, repeated panel grid |
| Connection options | Interlocking-edge or dry-hung arrangements | Independent panel connections with a joint treatment |
| Joint treatment | Matched edge and connection geometry | Open joint filled with weather-resistant sealant over backer rod |
| Fabrication envelope | Maximum panel length 4,000 mm | Maximum panel length 4,000 mm |
| Best drawing priority | Edge engagement and installation direction | Joint width, sealant geometry and panel alignment |
Lianhui’s close-joint panels use interlocking edges or dry-hung fittings; the expressed-joint system leaves a gap filled with weather-resistant sealant over backer rod. Order one complete detail rather than mixing the look of one with the hardware of the other.
Should the drawing show panel size or module size?
Show both. Face size is the fabricated panel; module size is the repeat distance, equal to face plus joint on a regular grid. Keeping them separate prevents errors adding up at corners, openings and the last panel in a row.
- Dimension the starting datum and the end at each wall or return.
- Mark every change in joint direction, width or finish.
- Draw a joint section with face, folded returns, bracket and subframe.
- Carry building movement joints through the cladding.
With a 600 mm module and 10 mm joints, each face is 590 mm. Eight faces and seven joints occupy (8 × 590) + (7 × 10) = 4,790 mm before perimeter clearances. Order 600 mm as the face size by mistake and the row grows to 4,870 mm, 80 mm too long.
Does a narrow joint make panel replacement easier?
Replacement depends on the connection and the movement available, not the visible gap. Interlocking edges follow a set installation sequence; dry-hung panels need room to lift off their hooks. Keep that route clear beside lights, wall returns and other fixed obstructions.
Draw an enlarged section at the tightest location, trace the actual removal direction and list what comes off first. That gives a serviceable facade without an access hatch in every bay.
| Connection | Installation consequence | Replacement planning |
|---|---|---|
| Interlocking-edge close joint | Neighboring edges engage in a defined direction | Retain the sequence and access to the parts released first. |
| Dry-hung close joint | Panel hooks engage fittings on the support frame | Keep the required lift and release movement clear. |
| Expressed joint with sealant | Backer rod and sealant complete the visible joint | Include removal and reinstatement of the joint finish in the replacement procedure. |
Is an expressed joint automatically a ventilated rainscreen?
A visible joint is an appearance choice. A rainscreen also needs an engineered cavity, drainage, ventilation, weather barrier and fire strategy, and a sealed joint behaves differently from an open drained one. Specify the full wall assembly.
Which system should appear in the purchase specification?
Specify interlocking or dry-hung close-joint panels when a continuous surface is the priority, and expressed-joint panels with the sealant-filled open-joint detail when the design uses a visible outdoor grid. Supports, thermal movement and the wall build-up apply to both.
For comparable quotes, put face size, developed size, thickness (1.5–3.0 mm), coating (powder, PVDF or wood-grain), brackets, joint finishing and perimeter details on one schedule, and check whether framing and joint treatment are included in each m² rate.
Use the 2.5 vs 3 mm thickness guide to match thickness to span and supports, and release the panel layout and joint section together so factory and installer work to the same dimensions.
Buying in volume? Standard ceilings ship from 150–200 m² in 15–20 working days. Get wholesale prices → · Custom project? Send drawings →